Manufacturing & Design Basis

Compression-Molded FRP Grating

Glass roving and continuous strand are laid in both directions and compression-molded with thermoset resin, producing a truly bi-directional panel.

Compression molding

Fibrous glass is pre-formed and molded under heat and pressure in a single tool, locking the bi-directional grid into a rigid, integral panel — no secondary bonding.

Bi-directional strength

Load is carried in both panel directions, so molded grating performs reliably regardless of bar orientation relative to the span.

Glass content ≈ 33%

Typical glass loading is 33% ± 3% by weight (resin-rich, corrosion-dominant laminate), vs. ~70% for pultruded grating.

Standard panel size1220 × 3660 mm (≈ 4' × 12') — most stocked
Other standard panels1000 × 3000 mm · 1220 × 2440 mm · cut-to-size available
Standard meshes38 × 38 mm (rectangular / square) · 19 × 19 mm mini-mesh · 25 × 100 mm rectangular
Complete Specification Matrix

Standard molded configurations — section properties per metre of width

I = moment of inertia per m width; Z = section modulus per m width. Panel weight based on 1220 × 3660 mm (4.465 m²). Spans/loads are indicative for pedestrian service.

ThicknessMeshOpen AreaWeight (kg/m²)Panel Weight (kg, 1220×3660)I (cm⁴/m)Z (cm³/m)Max Span @ L/200 (mm)Max Uniform Load @ 1 m span (kN/m²)
25 mm38 × 38 mm70%12.756.719.115.6≈ 900≈ 8.5
25 mm19 × 19 mm (mini-mesh)50%14.564.733.025.0≈ 850≈ 9.0
30 mm38 × 38 mm70%15.067.034.022.0≈ 1050≈ 13
38 mm38 × 38 mm70%18.683.069.634.9≈ 1250≈ 23.5
38 mm19 × 19 mm (mini-mesh)44%22.098.297.542.6≈ 1200≈ 26
40 mm38 × 38 mm70%19.587.180.040.0≈ 1300≈ 27
50 mm38 × 38 mm70%21.596.0130.052.0≈ 1500≈ 33
50 mm19 × 19 mm (mini-mesh)45%28.0125.0180.072.0≈ 1450≈ 36

Molded section properties (I, Z, weight, open area) are consistent with industry molded-grating technical catalogs (manufacturer data); spans and uniform loads are indicative and derived from manufacturer load tables for pedestrian live load. Verify against certified load/span charts for your exact resin and surface. Source: Industry molded-grating technical catalogs (manufacturer data); ZeAllgrate (ACMA) design guidelines; ASTM D638 / D790 / D695 / D792 / D570 / E84.

Physical & Mechanical Properties

Typical laminate values per ASTM test methods

Values are typical production-panel properties. Use characteristic (minimum) design values per ASTM D7290 for engineering design.

PropertyTest MethodTypical Value
DensityASTM D7921.8 – 2.0 g/cm³ (≈ 0.065 – 0.072 lb/in³)
Glass contentCombustion / ignition loss33% ± 3% by weight
Tensile strength (laminate)ASTM D638≈ 80 – 100 MPa (typical)
Flexural strength (laminate)ASTM D790≈ 150 – 200 MPa (typical)
Flexural modulusASTM D790≈ 10,000 – 12,000 MPa (typical)
Compressive strengthASTM D695≈ 150 – 200 MPa (typical)
Water absorption (24 h)ASTM D570< 0.5%
Barcol hardnessASTM D2583> 40
Thermal conductivityASTM C177 / ISO 83020.3 – 0.5 W/(m·K)
Coeff. of thermal expansion (in-plane)ASTM D696≈ 12 × 10⁻⁶ /°C
Coeff. of thermal expansion (through-thickness)ASTM D696≈ 80 × 10⁻⁶ /°C
Dielectric strengthASTM D149> 10 kV/mm (inherent insulation)

Tensile/flexural/compressive values are typical laminate values for molded FRP (bi-directional, ~33% glass) and are not interchangeable with unidirectional pultruded coupon data. Exact values supplied on the batch COA. Source: Industry molded-grating technical catalogs (manufacturer data); ZeAllgrate (ACMA) design guidelines; ASTM D638 / D790 / D695 / D792 / D570 / E84.

Resin Systems Available

Match the resin to the media, concentration and service temperature

Tg is the glass-transition temperature; max continuous service temperature is the long-term design limit.

Resin SystemTg (typical)Max Service Temp.Chemical Resistance SummaryFire PerformanceTypical Application
ZeAll Ortho (general purpose)≈ 80 – 100 °C Tg≈ 60 °CGood general/corrosion; water, mild acids/basesSelf-extinguishing (ASTM D635); E84 ≤ 25 typicalGeneral walkways, sewage, water treatment
ZeAll ISO (corrosion grade)≈ 110 – 120 °C Tg≈ 80 °CImproved acid/alkali resistance over orthoSelf-extinguishing; E84 ≤ 25Chemical plants, plating, scrubbers
ZeAll VE (vinyl ester)≈ 130 – 150 °C Tg≈ 90 °CExcellent — acids, solvents, oxidizers, bleachSelf-extinguishing; E84 ≤ 25Harsh process areas, pulp & paper, offshore
ZeAll FR (fire-retardant VE)≈ 130 – 150 °C Tg≈ 90 °CExcellent corrosion + low flame spread / low smokeE84 Class A (≤ 25, low smoke); USCG / ABS optionsMarine, metro, enclosed/ventilated buildings
Phenolic≈ 180 °C+ Tg≈ 120 °C (long-term)Excellent fire/smoke performance; limited chemical rangeVery low smoke, self-extinguishing, no drippingPublic transport, tunnels, high-fire-risk zones

Fire-retardant grades achieve ASTM E84 flame spread index ≤ 25 (Class A/B) and are self-extinguishing per ASTM D635; low-smoke and marine approvals (USCG, ABS, DNV) available on request. Source: Industry molded-grating technical catalogs (manufacturer data); ZeAllgrate (ACMA) design guidelines; ASTM D638 / D790 / D695 / D792 / D570 / E84.

Surface Options

Coefficient of friction (COF) — wet and dry

COF values are indicative; grit-top provides the highest grip in wet/oily service.

SurfaceCOF (dry / wet)Open-Area EffectTypical Use
Concave (meniscus, standard)0.60 – 0.70 dry / 0.45 – 0.55 wetNo loss of open areaStandard molded profile — general industrial walkways
Convex0.55 – 0.65 dry / 0.40 – 0.50 wetNo loss of open areaImproved drainage, easy cleaning
Grit-top (silica carbide / quartz)0.75 – 0.85 dry / 0.55 – 0.70 wetSlightly reduced open areaWet, oily and chemical process areas — best grip
Smooth0.30 – 0.40 dry / 0.15 – 0.25 wetNo loss of open areaLight pedestrian / aesthetic; not for wet service
Colors, Tolerances & Dimensional Limits

Standard stock colors and fabrication tolerances

Standard colors: Green (RAL 6010) · Gray (RAL 7047) · Yellow (RAL 1003) · Red · Blue · Black. Custom Pantone / RAL matching available on request.

FeatureToleranceNote
Panel thickness± 1.0 mmMeasured at the bar centre
Panel dimensions (1220 / 3660 mm)± 3.0 mmLength and width
Squareness (diagonal)≤ 3.0 mmDifference of two diagonals
Flatness (warpage)≤ 3 mm per 1000 mmOver support span
Cut / drilled holesØ + 1.0 mmRadius corners to avoid stress concentration
Clip Selection Guide

Fastener type by grating thickness

Fasten every panel at every support intersection; minimum 4 hold-down clips per panel.

GratingRecommended ClipMaterial OptionsClips per PanelSpacing
25 mm moldedG-Clip (standard)SS304 / SS316 / galvanized≈ 6 – 8 per panel≈ 300 mm from edge; ≤ 1200 mm c/c at each support
30 mm moldedG-ClipSS304 / SS316 / galvanized≈ 6 – 8 per panel≤ 1200 mm c/c at each support
38 mm moldedG-Clip or M-ClipSS304 / SS316 / galvanized≈ 6 – 8 per panel≤ 1200 mm c/c at each support
50 mm moldedM-Clip (heavy-duty)SS304 / SS316 / galvanized≈ 8 per panel≤ 1200 mm c/c; minimum 4 clips per panel
Pultruded 40 – 60 mmG-Clip / saddle clipSS304 / SS316≈ 4 – 6 per panelAt every bearing-bar / support intersection

G-Clip for standard molded thicknesses; M-Clip for 50 mm heavy panels. In coastal/marine or chemical service, specify SS316 over galvanized to avoid galvanic corrosion. See the Accessories Catalog for full fastener selection.

Data Sources

  • Industry molded-grating technical catalogs (manufacturer data) — molded load/span, section matrix, fire & thermal data.
  • ZeAllgrate (ACMA) Guidelines for the Engineer / Designer — pedestrian design criteria, deflection limits, ASTM D7290 characteristic method.
  • ASTM test methods: D638 (tensile), D790 (flexural), D695 (compressive), D792 (density), D570 (water absorption), E84 (surface burning).

Engineers should specify from certified load/span charts for the exact resin, thickness and surface. ZeAllgrate supplies load test reports and material certificates (COA) with every shipment. Contact [email protected] for project-specific data.

Certified & Verified

Approved by Industry Bodies, Tested to International Standards

Every ZeAllgrate shipment is backed by documented quality systems, marine approvals and independent third-party verification.

Q

ISO 9001:2015

Certified quality management system — since 2004.

⚓

DNV & ABS Marine

Marine-grade grating for offshore platforms and vessel decks.

✔

SGS & Intertek

Independent third-party inspection and load testing on request.

🛡

OSHA 1910.23

Handrail systems load-tested to US federal requirements.

Material certificates, COA, ASTM test reports and compliance documentation supplied with every order. View certifications →

Need a Certified Specification for Your Project?

Send your span, load, deflection limit and media — our engineers return a panel recommendation, load chart and COA within 24 hours.