ISO 9001 Certified · FRP/GRP Grating Manufacturer · Since 2004 · Exporting to 45+ Countries

FRP Load & Span Calculator

Simply-supported beam deflection estimate in your browser

Calculator

FRP Grating Load & Span Calculator

Estimate simply-supported beam deflection for a 1-metre-wide strip of grating. UDL formula: δ = 5wL⁴ / (384EI). Point-load formula: δ = PL³ / (48EI). Molded E = 10,000 MPa; pultruded E = 20,000 MPa. Section I = b·h³/12 per metre width (b = 1000 mm).

1 · Inputs

Mesh size affects open area, fall-through and impact resistance; this simplified deflection model treats the panel as a solid strip, so mesh does not alter the estimate. Certified load/span charts differentiate mesh geometry.

Result

Run the calculation to see a verdict.

Enter your inputs and press Calculate Deflection — PASS / FAIL, computed vs. allowed deflection, utilisation and a recommended next thickness.

Disclaimer: this is an indicative estimation tool, NOT a substitute for certified load/span charts or professional engineering judgment. It uses a simplified beam model on representative moduli and does not include safety factors, impact, fatigue, temperature derating or support detail. Final design per ZeAllgrate guidelines and ASTM D790/D638, verified by ZeAllgrate engineering.
Reading the Result

What the Numbers Mean

OutputDefinitionHow to Use It
Computed deflection δPredicted mid-span sag under the applied load (mm).The actual sag the panel would show, per the simplified beam model.
Allowed deflectionL / deflection-limit ratio (e.g. L/150 = span ÷ 150).The sag your chosen code permits. Compare computed vs. allowed.
Utilisation %Computed deflection ÷ allowed deflection × 100.Below 100% = PASS. Approach 100% = no reserve; above 100% = FAIL.
Recommended thicknessThe next panel thickness that meets the limit at the same span.If the current panel fails, step up in thickness (or move to pultruded).

Need the Certified Load Chart?

Send your span, UDL, point load and deflection limit — we return the exact panel and the certified load/span table.

Design basis: ZeAllgrate (Fiberglass Grating Manufacturers Council / ACMA) design guidelines; ASTM D790 (flexural properties), ASTM D638 (tensile), ASTM D648 (heat deflection) and ASTM E84 (surface burning). Resin property data based on Ashland / Reichhold technical datasheets. All outputs are INDICATIVE estimates for specification guidance only — they are NOT a substitute for certified load/span charts, approved resin datasheets or professional engineering judgment. Final design must be verified by ZeAllgrate engineering.