FRP / GRP
Fiber-Reinforced Polymer (Glass-Reinforced Plastic). A composite of glass fibers embedded in a polymer resin — the material of ZeAllgrate grating.
Molded Grating
Grating made by compression-molding continuous glass roving in two directions in a mold; bi-directional strength, ~33% glass content, excellent impact resistance.
Pultruded Grating
Grating built from pultruded load-bearing bars (I or T profile) tied by cross bars; ~70% glass content, roughly twice the stiffness of molded.
Meniscus
The smooth resin-rich top skin formed on molded grating during molding; a wear surface that protects the fibers and can be concave, convex or smooth.
Pultrusion
A continuous manufacturing process pulling glass fibers through a resin bath and a heated die to form constant-cross-section profiles (bearing bars, tubes).
Barcol Hardness
Indentation hardness of the rigid surface (tested per ASTM D2583); used to confirm resin cure and surface consistency.
Open Area
The percentage of the panel face that is void (open holes). Standard 38×38 mesh ≈ 70%; Mini-Mesh ≈ 44%; HLC ≈ 48%. Affects drainage and fall-through.
Hold-down Clip
A fastening (G-clip / L-clip) that secures the panel to its support; stainless steel SS304/316 in corrosive service; allows controlled thermal sliding.
Grit-Top
An abrasive silica grit bonded into the top surface for maximum wet/oily slip resistance.
Bearing Bar
The primary load-carrying bar in pultruded grating (I or T profile); must span across the support.
Tie Bar
The cross bar connecting bearing bars (e.g. 152 mm pitch, flush-top) — does NOT carry primary load.
Deflection
The vertical sag under load; limited by ratio L/100, L/150, L/200 or an absolute cap (e.g. 3/8 in).
Span (Clear Span)
The clear distance between supports; the primary variable controlling allowable load.
Resin
The polymer matrix that binds and protects the glass: isophthalic polyester, vinyl ester, phenolic, etc. Determines corrosion, fire and temperature behavior.
Glass Content
Weight/volume fraction of glass reinforcement. Molded ~33%, pultruded ~70%; higher glass = higher strength and stiffness.
Isophthalic (Polyester)
A mid-grade polyester resin; the cost-effective workhorse for moisture, mild acids/alkalis and general corrosion.
Vinyl Ester
A high-performance resin with ester end-groups; resists strong acids, oxidizers and chlorine bleach that degrade polyester.
Phenolic
A thermoset resin with inherently low flame spread and low smoke; used in tunnels and escape routes.
UV Stabilizer
An additive that protects the resin from ultraviolet degradation, chalking and fading outdoors.
Fire Retardant (FR)
A resin formulation (or additive) that reduces flame spread and slows ignition; rated via ASTM E84.
Concave Surface
A dished/dimpled meniscus that channels water off the walking surface; standard slip-resistant texture.
Convex Surface
Raised rounded protrusions on the top surface; the other standard textured option.
Smooth Surface
A flat, non-textured meniscus; used in cleanrooms and food contact where grit would trap residue.
Mini-Mesh
Small-opening grating (~12.7–19 mm, ~44% open area) that prevents tools and small objects falling through openings.
HLC
High-Load-Capacity molded grating series (≈48% open area); engineered for heavier loads than standard mesh.
I-Beam (I-bar)
An I-shaped pultruded bearing bar (e.g. I-4010, I-6010, I-4015, I-6015); high stiffness-to-weight.
T-Bar (T-bar)
A T-shaped pultruded bearing bar (e.g. T-3320, T-5020); efficient section for heavy, long-span decks.
Flush-Top
A grating where the tie bar sits level with the bearing-bar top (e.g. 152 mm flush-top tie), giving a consistent walking plane.
Slip Resistance
The ability of a walking surface to resist slipping; evaluated by coefficient of friction.
COF (Coefficient of Friction)
Ratio of friction force to normal force; higher = safer; wet COF is the critical value.
Thermal Expansion (CTE)
Coefficient of thermal expansion; FRP moves more than steel in resin-rich directions and must be jointed/slotted.
Corrosion Resistance
Resistance to chemical/atmospheric degradation; governed almost entirely by resin choice.
Chemical Resistance
Compatibility of the resin with specific chemicals at given concentrations and temperatures.
Load Table / Load Chart
A tabulated chart of allowable load vs. span for a panel at a given deflection limit.
Span Table
Tabulated maximum clear spans per panel thickness/load.
Uniform Load (UDL)
Load spread over area, in kN/m² or psf (e.g. pedestrian walkway 50–65 psf).
Concentrated Load
A single point load, in kN or lbf (e.g. a wheel or machine foot).
Safety Factor
The divisor applied to ultimate capacity (typically 4:1–5:1 per ZeAllgrate) to derive working load.
Modulus of Elasticity (E)
Stiffness of the material (ASTM D790 flexural modulus); controls deflection.
Flexural Strength
Strength in bending (ASTM D790); controls failure under load.
Tensile Strength
Strength under axial pull (ASTM D638).
Compressive Strength
Strength under crushing load (ASTM D695); relevant at supports.
Density
Mass per unit volume (ASTM D792); used to verify panel weight (kg/m²).
Water Absorption
Moisture uptake over time (ASTM D570); indicates long-term wet durability.
Dielectric Strength
Electrical insulation property; why FRP is used in substations and live areas.
Thermal Conductivity
Heat transfer through the material; FRP is a good thermal insulator versus steel.
Barcol
See Barcol Hardness — surface hardness measure.
ASTM
American Society for Testing and Materials; publisher of the test-method standards D638, D790, E84, etc.
ISO
International Organization for Standardization; e.g. ISO 14122 for permanent machinery access.
OSHA
US Occupational Safety and Health Administration; 29 CFR 1910.23 governs walking-working surfaces.
ADA
Americans with Disabilities Act; accessibility and slip-resistance requirements for public routes.
NEMA
National Electrical Manufacturers Association; standards relevant to non-conductive fiberglass products.
FM Approval
Factory Mutual / fmGlobal approval — insurance-driven certification for fire/hazard applications.
Section Modulus (Z)
A beam section property relating to bending strength; allowable load scales with Z.
Moment of Inertia (I)
A beam section property relating to stiffness; deflection scales inversely with I.
Edge Banding
FRP flat-bar edging bonded to cut edges for impact protection and appearance.
Toe Board
A low barrier at platform edges (OSHA-required) to stop objects falling; specified with the grating.
Steiner Tunnel
The test apparatus behind ASTM E84 measuring flame spread and smoke developed.
Flame Spread Index (FSI)
ASTM E84 rating of how quickly flame spreads across a surface.
Smoke Developed Index (SDI)
ASTM E84 rating of smoke density produced during burning.
Compression Molding
The molded-grating process: chopped mat and continuous roving loaded into a two-part steel mold, impregnated with resin and pressed under heat to cure.
Resin Transfer Molding (RTM)
A closed-mold process where resin is injected into a fiber preform under low pressure; used for complex, high-consistency parts.
Filament Winding
Winding continuous rovings under controlled tension onto a mandrel to build tubular or rotational parts; relevant to related FRP profiles, not typical for grating panels.
Cure Cycle
The time-temperature schedule during molding that converts liquid resin into a solid thermoset; under-cure lowers strength and chemical resistance.
Post-Cure
A secondary oven or warm-air treatment after demolding that raises crosslink density, Barcol hardness and heat/chemical resistance.
Gel Coat
A thin, pigmented resin-rich outer layer applied to the mold surface before reinforcement, giving a smooth, cosmetic and corrosion-resistant face.
Surfacing Veil (C-Veil)
A thin, non-woven glass or synthetic surface mat placed at the mold face to produce a resin-rich, fiber-free surface layer that improves corrosion and UV resistance.
E-Glass
Electrical-grade low-alkali glass, the standard reinforcement for FRP grating; good strength and cost balance, moderate alkali resistance.
S-Glass
High-strength magnesium-alumina glass with roughly 15–30% higher tensile strength and modulus than E-glass; used in high-performance applications.
AR-Glass
Alkali-resistant glass containing zirconia; used in cement/concrete reinforcement, not typical for grating.
Roving
A bundle of parallel continuous glass filaments supplied as a single strand; the primary reinforcement form for pultrusion and molded preforms.
Continuous Strand Mat
A randomly laid, non-woven mat of continuous glass strands held by a binder; gives multi-directional in-plane strength in molded parts.
Woven Roving
A woven fabric of roving bundles (0°/90°); used where balanced directional strength is needed in laminates.
Chopped Strand
Short (25–50 mm) glass fibers cut from roving; dispersed in the resin mix to add random, low-cost reinforcement.
Shear Strength
The stress at which material fails by sliding along a plane; critical for bearing bars at supports and tie-bar joints.
Poisson's Ratio
The ratio of lateral strain to axial strain under load; FRP is orthotropic so this varies by direction; used in plate-bending and bearing calculations.
Fatigue Strength
The stress a material can survive for a given number of repeated load cycles; relevant to vibrating machinery decks and forklift traffic.
Creep
Time-dependent deformation under sustained constant load; FRP creeps more than steel at high temperature, so long-duration loads need a knockdown factor.
Stress Relaxation
The decrease in stress over time under a fixed strain; relevant to bolted connections pre-torqued at temperature extremes.
Izod Impact Strength
Notched pendulum impact energy per ASTM D256; measures notch sensitivity and toughness.
Charpy Impact Strength
Pendulum impact test (ISO 179 / ASTM D6110); complements Izod for toughness comparison of FRP.
Bearing Strength
The compressive stress a material withstands perpendicular to a fastener hole; FRP bearing strength is typically ~150–200 MPa, much lower than steel.
Interlaminar Shear Strength (ILSS)
The shear stress between plies in a laminate (tested by short-beam shear ASTM D2344); governs delamination risk.
Hydrolysis
Chemical decomposition of the resin ester linkages by water, especially at elevated temperature; the main long-term degradation path of polyester in hot wet service.
Oxidation
Degradation of the resin by oxygen or oxidizers (e.g. bleach, chromic acid); vinyl ester resists it better than polyester.
Solvent Swelling
Dimensional and softening change when resin absorbs organic solvents; a resin's resistance list flags solvents that cause it.
Blistering
Localized surface delamination caused by osmotic pressure or trapped moisture vaporizing under heat; visible as raised bubbles.
Chalking
Powdery surface residue formed when the resin binder erodes away, exposing glass fibers; the visible sign of UV or chemical surface degradation.
Fiber Bloom
Exposure of glass fibers at the surface as the resin layer wears or chalks; cosmetic but accelerates further degradation if left unsealed.
Erosion
Material loss by abrasion or fluid impact (e.g. slurry, sand-blast); grit-top and resin-rich surfaces resist it longer.
Corrosion Allowance
Extra resin grade or design margin built in to tolerate expected chemical attack over the design life.
ASTM D2344
Standard test for short-beam strength, used to measure interlaminar shear strength (ILSS) of FRP.
ASTM C581
Practice for measuring chemical resistance of thermoset-reinforced equipment by weight, Barcol and flexural retention after exposure.
ASTM D648
Test for heat deflection temperature (HDT) — the temperature at which a bar deflects a fixed amount under a given load.
ISO 527
International standard for tensile properties of plastics (parts 1–5); the non-US equivalent of ASTM D638 for FRP.
ISO 14125
International standard for flexural properties of fiber-reinforced plastic composites.
NACE TM0174
NACE test method for laboratory corrosion testing of thermoset resin coatings and linings in acidic environments.
Effective Width
The portion of a wide flange or panel that actually participates in bending; used when calculating wide-panel flexural capacity.
Orthotropic Plate
A plate with different stiffness in two perpendicular directions (e.g. pultruded bearing bars vs. tie bars); modeled differently from isotropic steel.
Web Crippling
Local crushing failure of a thin section web under concentrated support or reaction loads; checked on I/T-bar webs at supports.
Bearing Length
The length of contact between a panel end and its support; molded panels need ≥50 mm, pultruded ≥75 mm minimum.
End Reaction
The vertical shear force delivered by a bearing-bar end into the support; used to check web crippling and clip capacity.
Continuous Span
A panel or beam spanning over more than one support, where negative moment develops over the intermediate supports.
Simple (Simply Supported) Span
A single span between two supports with no moment transfer at the ends; the standard assumption for grating design.
Cantilever
A projection beyond a support with a free end load; requires special check for top-surface tension and end uplift.
Load Duration Factor
A reduction applied to long-duration (dead) load versus short-duration (live) load to account for creep and creep rupture.
Knockdown Factor
A divisor applied to short-term material properties to account for temperature, moisture, fatigue or long-term loading.
Shim
A thin tapered or flat plate inserted under a panel or support to level it or adjust bearing height.
Packer
A load-bearing spacer block placed under a grating panel to bridge a gap in the support structure.
Setting Block
A fixed block used to position and align grating panels during installation; controls consistent gaps.
Expansion Joint
A deliberate gap or sliding assembly that accommodates thermal movement between panel runs.
Slip Joint
A connection that allows sliding movement along one axis while still transferring load perpendicular to it.
Through-Bolt
A bolt passing through the grating panel and support flange; the FRP equivalent of a welded connection, with washers to distribute load.
Bonded Joint
A joint made with adhesive (epoxy, methacrylate) rather than mechanical fasteners; preferred for fatigue and vibration.
Mechanical Fastening
Joining by bolts, screws or clips; allows disassembly but creates hole stress concentrations.
ASME
American Society of Mechanical Engineers; publishes boiler/pressure-vessel and piping codes that reference FRP in corrosive service.
AISC
American Institute of Steel Construction; its steel design tables are the comparison baseline for FRP decking.
ACI
American Concrete Institute; relevant where FRP contacts concrete and rebar in mixed structures.
NFPA
National Fire Protection Association; NFPA 70 (NEC), NFPA 70E (arc flash) and NFPA 255 (ASTM E84) govern FRP fire and electrical use.
IBC
International Building Code; the dominant US model building code that references live loads, fire ratings and access.
UBC
Uniform Building Code; the predecessor to IBC, still referenced in older project specifications.
Eurocode
The European structural design code suite (EN 1990–1999); EN 13706 covers pultruded FRP grilles and profiles.
BS EN
British Standards / European Norm harmonized standards; BS 4592 is the UK industrial flooring standard.
JIS
Japanese Industrial Standards; JIS-related standards govern FRP grating in the Japanese market.
AS/NZS
Joint Australian/New Zealand standards; AS 1657 covers fixed platforms, ladders and walkways.
Laminate
A stack of plies (layers of reinforcement and resin) built up to form a composite part.
Ply
A single layer of reinforcement within a laminate.
Layup
The arrangement and sequence of plies placed in a mold before consolidation and cure.
Stacking Sequence
The ordered list of ply orientations (e.g. 0°/90°/±45°) that determines laminate directional properties.
Volume Fraction (Vf)
The percentage of composite volume occupied by fibers; the primary driver of stiffness and strength.
Weight Fraction (Wf)
The percentage of composite weight occupied by glass; ~33% molded, ~70% pultruded.
Void Content
The percentage of trapped air voids in a laminate; measured by microscopy or burn-off; low voids (<1–2%) are required for corrosion resistance.
Glass Transition Temperature (Tg)
The temperature at which resin transitions from a rigid glass to a softer rubbery state; above Tg, mechanical and electrical properties collapse.
Heat Deflection Temperature (HDT)
The temperature at which a standard bar deflects 0.25 mm under a specified outer fiber stress (ASTM D648); an upper-service-temperature indicator.
Flammability
How easily a material ignites and sustains flame; rated by ASTM E84, UL 94 or limiting oxygen index.
Ignition Temperature
The minimum temperature at which the material self-ignites in air; a fire-safety parameter for thermal environments.
Limiting Oxygen Index (LOI)
The minimum oxygen concentration that supports combustion (ASTM D2863); higher LOI means harder to burn.
Smoke Density
The optical density of smoke produced by burning (e.g. ASTM E662 / NBS chamber); critical in enclosed-space fire codes.
Toxicity Index
A rating of toxic gas yield during combustion; phenolic resins score far lower than standard polyester.
Mesh Opening
The grid spacing of the panel (e.g. 38 × 38 mm); determines drainage, debris retention and foot-traffic behaviour.
Working Load
A load table basis that already includes the safety factor; used directly in design without further reduction.
Ultimate Load
A load table basis without the safety factor; the project factor must be applied before comparison with service loads.
COA / Certificate of Analysis
Documentation of the delivered batch — resin grade, test values and traceability — matching the shipment to the order.
Incoterms
International trade terms defining delivery, risk and cost transfer between buyer and seller (e.g. FOB, CIF, EXW).
Slip-Clamp
A fixing that allows the panel to slide under thermal movement; one end of a run is slip-clamped, the other fixed.
Edge Sealing
Resin sealing of cut edges at openings and notches to prevent moisture ingress into the laminate.
L/200
The deflection limit expressed as span divided by 200 — the walkway default; stricter limits apply in cleanrooms and vibration-sensitive decks.
Thermal Movement
Length change of the panel with temperature (FRP expands more than steel); managed with gaps and slip-clamped ends.
Corrosion Barrier
The resin-rich surface layer (veil plus mat) that protects the structural laminate from chemical attack.
UV Degradation
Gradual surface change (chalking) of the resin under sunlight; managed with UV-stabilised grades; cosmetic, not structural.
Static Load
A load applied steadily (equipment, stored material); designed against the long-term capacity.
Dynamic Load
A load that varies with time (foot traffic, machinery); designed with vibration and fatigue checks on long spans.
Galvanic Corrosion
Accelerated attack where dissimilar metals contact in a wet electrolyte; avoided by matching hardware alloys and isolating interfaces.
Resin-Rich Surface
A surface with high resin content (behind the veil) that resists chemical ingress better than exposed glass.
Fabrication Drawing
The approved shop drawing for custom sizes, cut-outs and notches; the contract between design intent and the manufacturing shop.

Term Not Found?

Ask our engineers — we maintain this glossage alongside real project questions.

Source: ZeAllgrate (Fiberglass Grating Manufacturers Council / ACMA) design guidelines; ASTM International; ISO 14122; OSHA 29 CFR 1910. Indicative data for specification guidance only — final design verified by ZeAllgrate engineering against certified load/span charts.